Impact of self-contact lens fitting with uncorrected refractive error on visual acuity and lens movement in contact lens wearers

Authors

  • Pussadee Paensuwan Naresuan University, Phitsanulok, Thailand
  • Pavasut Leedasawat Naresuan University, Phitsanulok, Thailand
  • Wanachat Chaiyasan Naresuan University, Phitsanulok, Thailand
  • Darawan Pejchang Naresuan University, Phitsanulok, Thailand

Keywords:

Contact lenses fitting, eye practitioners, refractive errors, best-corrected visual acuity, lens movement

Abstract

Background: Contact lenses are increasingly popular for refractive error correction. An eye examination and contact lens fitting for individual wearers are very important for best visual acuity and fitting accomplishment. Most Thai contact lens users buy their lenses from local shops and fitted the lens themselves without professional eye care services. This article reports on the impact of self-contact lens fitting on visual acuity and lens movement to establishes the requirement of contact lens access control.

Objectives: To investigate the impact of self-contact lens fitting focusing on the uncorrected refractive error via visual acuity measurement and to determine the effect of lens base curve on lens movement in contact lens wearers.

Methods: A total of sixty eyes of 30 contact lens wearers were recruited. The contact lens parameters were taken from the lenses’ package. Corneal curvature was determined using corneal topography. A best-corrected visual acuity and over-refraction were assessed by placing contact lens of the subjects with or without prescription using a phoropter and a distance chart for Early Treatment Diabetic Retinopathy Study (ETDRS). Lens movement was determined for a proper fitting via ocular micro-bioscope.

Results: All subjects used contact lenses with 8.6 mm base curves and 14.2 mm diameters. All of them bought their lenses without a prescription. There was a significant difference between corrected spherical equivalent refraction and subject’s contact lens power (P < 0.001). The poor visual acuity with the subject’s lenses was significantly improved upon over-refraction (P < 0.001). Only half of eligible eyes qualified for an optimal lens movement with their recent contact lens.

Conclusion: The self-contact lens fitting without eye examination might induce lens complications. There is a high prevalence of contact lens wearers who fitted their lenses depending on their own decision without an eye examination. There is 91.7% of subjects who required an over-refraction to achieve the best visual acuity. Only half of eligible eyes showed appropriate lens movement with the contact lens used. A regular contact lens assessment by eye practitioners should be done prior to and during using contact lens for improvement of best vision.

Downloads

Download data is not yet available.

References

Naidoo KS, Jaggernath J. Uncorrected refractive errors. Indian J Ophthalmol 2012;60:432-7.

https://doi.org/10.4103/0301-4738.100543

Smith TS, Frick KD, Holden BA, Fricke TR, Naidoo KS. Potential lost productivity resulting from the global burden of uncorrected refractive error. Bull World Health Organ 2009;87:431-7.

https://doi.org/10.2471/BLT.08.055673

Holden BA, Sulaiman S, Knox K. The challenge of providing spectacles in the developing world. Community Eye Health 2000;13:9-10.

Weih LM, VanNewkirk MR, McCarty CA, Taylor HR. Age-specific causes of bilateral visual impairment. Arch Ophthalmol 2000;118:264-9. https://doi.org/10.1001/archopht.118.2.264

Lansingh C, Eckert A. VISION 2020: The right to sight in 7 years? Med Hypothesis Discov Innov Ophthalmol 2013;2:26-9.

Jenchitr W, Raiyawa S. Refractive errors: the major visual impairment in Thailand. Rangsit J Arts Sci 2012;2:133-41.

Yingyong P. Refractive errors survey in primary school children (6-12 year old) in 2 provinces: Bangkok and Nakhonpathom (one year result). J Med Assoc Thai 2010;93:1205-10.

Vu HT, Keeffe JE, McCarty CA, Taylor HR. Impact of unilateral and bilateral vision loss on quality of life. Br J Ophthalmol 2005;89:360-3. https://doi.org/10.1136/bjo.2004.047498

Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, et al. The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Arch Ophthalmol 2004;122:495-505. https://doi.org/10.1001/archopht.122.4.495

Royal Thai Government Gazette. Notification of Ministry of Public Health "contact lens". Bangkok: Royal Thai Government Gazette; 2010. Volume 127, Special Part 120, p. 41.

Tajunisah I, Ophth M, Reddy SC, Phuah SJ. Knowledge and practice of contact lens wear and care among medical students of University of Malaya. Med J Malaysia 2008;63:207-10.

Beljan J, Beljan K, Beljan Z. Complications caused by contact lens wearing. Coll Antropol 2013;37 Suppl 1:179-87.

Belda-Salmeron L, Drew T, Hall L, Wolffsohn JS. Objective analysis of contact lens fit. Cont Lens Anterior Eye 2015;38:163-7. https://doi.org/10.1016/j.clae.2015.01.006

Wolffsohn JS, Hunt OA, Basra AK. Simplified recording of soft contact lens fit. Cont Lens Anterior Eye 2009;32:37-42. https://doi.org/10.1016/j.clae.2008.12.004

Imsumran S. Purchasing behavior for big eye contact lens among female student of Chetupon Commercial Colledge. Pathum Thani: Rajamangala University of Technology Thanyaburi; 2011.

Munsuk S, Chalongsuk R. Knowledge of youth towards fashionable contact lens. Thai Bulletin of Pharmaceutical Sciences 2013;8:21-34.

González-Cavada J, Corral O, Niño A, Estrella MA, Fuentes JA, Costa-Madrid D. Base curve influence on the fitting and comfort of the senofilcon A contact lens. J Optom 2009;2:90-3.

https://doi.org/10.3921/joptom.2009.90

Fan L, Jia Q, Jun J, Jie C. Base curve selection of disposable contact lenses for Chinese wearers. Int Contact Lens Clin 1996;23:27-9. https://doi.org/10.1016/0892-8967(95)00113-1

Dumbleton KA, Chalmers RL, McNally J, Bayer S, Fonn D. Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses. Optom Vis Sci 2002; 79:633-7. https://doi.org/10.1097/00006324-200210000-00008

Santodomingo-Rubido J, Rubido-Crespo MJ. The clinical investigation of the base curve and comfort rate of a new prototype silicone hydrogel contact lens. Eye Contact Lens 2008;34:146-50.

https://doi.org/10.1097/ICL.0b013e3181506bbd

Young G. Evaluation of soft contact lens fitting characteristics. Optom Vis Sci 1996;73:247-54.

https://doi.org/10.1097/00006324-199604000-00006

Young G. Why one million contact lens wearers dropped out. Cont Lens Anterior Eye 2004;27:83-5.

https://doi.org/10.1016/j.clae.2004.02.006

Latham K, Katsou MF, Rae S. Advising patients on visual fitness to drive: implications of revised DVLA regulations. Br J Ophthalmol 2015;99:545-8. https://doi.org/10.1136/bjophthalmol-2014-306173

Abbouda A, Restivo L, Bruscolini A, Pirraglia MP, De Marco F, La Cava M, et al. Contact Lens Care among Teenage Students in Italy: A Cross-Sectional Study. Semin Ophthalmol 2016;31:226-32.

Lee YC, Lim CW, Saw SM, Koh D. The prevalence and pattern of contact lens use in a Singapore community. CLAO J 2000;26:21-5.

Morgan PB, Efron N, Woods CA, Jones D, Grein HJ, Tranoudis IG, et al. International contact lens prescribing in 2004. Contact Lens Spectrum 2005;20:34-7

Alipour F, Khaheshi S, Soleimanzadeh M, Heidarzadeh S, Heydarzadeh S. Contact lens-related complications: a review. J Ophthalmic Vis Res 2017;12:193-204.

Young G, Coleman S. Poorly fitting soft lenses affect ocular integrity. CLAO J 2001;27:68-74.

Dumbleton KA, Chalmers RL, Richter DB, Fonn D. Changes in myopic refractive error with nine months' extended wear of hydrogel lenses with high and low oxygen permeability. Optom Vis Sci 1999;76:845-9. https://doi.org/10.1097/00006324-199912000-00020

Barnett WA, Rengstorff RH. Adaptation to hydrogel contact lenses: variations in myopia and corneal curvature measurements. J Am Optom Assoc 1977;48:363-6.

Meister DJ, Fisher SW. Progress in the spectacle correction of presbyopia. Part 1: Design and development of progressive lenses. Clin Exp Optom 2008;91:240-50.

https://doi.org/10.1111/j.1444-0938.2007.00245.x

Young G, Hall L, Sulley A, Osborn-Lorenz K, Wolffsohn JS. Inter-relationship of Soft Contact Lens Diameter, Base Curve Radius, and Fit. Optom Vis Sci 2017;94:458-65.

https://doi.org/10.1097/OPX.0000000000001048

Young G, Schnider C, Hunt C, Efron S. Corneal topography and soft contact lens fit. Optom Vis Sci 2010;87:358-66. https://doi.org/10.1097/OPX.0b013e3181d9519b

Downloads

Published

2023-08-15

How to Cite

1.
Paensuwan P, Leedasawat P, Chaiyasan W, Pejchang D. Impact of self-contact lens fitting with uncorrected refractive error on visual acuity and lens movement in contact lens wearers. Chula Med J [Internet]. 2023 Aug. 15 [cited 2024 Dec. 22];63(2). Available from: https://he05.tci-thaijo.org/index.php/CMJ/article/view/279