Kidney depth calculation by anterior and posterior renal scintigraphy using attenuation – related techniques

Authors

  • Tanawat Sontrapornpol King Chulalongkorn Memorial Hospital, The Thai Red Cross Society
  • Tawatchai Chaiwatanarat Faculty of Medicine, Chulalongkorn University
  • Chiramet Kawinthammasak King Chulalongkorn Memorial Hospital, The Thai Red Cross Society
  • Narongsak Kamklon King Chulalongkorn Memorial Hospital, The Thai Red Cross Society
  • Rinlaphat Rattanamonrot King Chulalongkorn Memorial Hospital, The Thai Red Cross Society

Keywords:

Kidney depth, renal scintigraphy, attenuation-related technique

Abstract

Background : Attenuation correction is one of important steps in calculation of renal function, either glomerular filtration rate (GFR) or effective renal plasma flow (ERPF), from nuclear medicine procedure. To do this correctly, depth of the kidney must be known. Generally, depth of the kidney can be calculated by some equation pre-installed in the machine’s computer using patient’s weight and height information. This technique will only result in estimated kidney depth values of the patients with the same equationderived population and will not be valid in patients from other population such as kidney transplanted patients.

Objective : To evaluate a more generalized and practical technique in calculation of kidney depth using attenuation-related technique.

Methods : By using anterior and posterior images of the body phantom with known width, the kidney depth is calculated using attenuation-related technique and compared with the actual value. The intra- and inter-operator variations are determined. The technique is applied in 98 patients of age 32.75 gif.latex?\pm 23.20 (average gif.latex?\pm SD) years old, including 30 children and 68 adults. The results on kidney depth are compared with other technique using lateral view images measurements and equation-derived kidney depth values.

Results : The phantom studies showed no significant intra-operator variations (deviation < 5%, P gif.latex?\geq 0.99) and inter-operator variations (P = 0.9995). The relationship of calculated kidney phantom depth and the actual value is close to the ideal straight line (r > 0.99). The studies in patients show good correlation with other techniques (r2 > 0.8099) and no significant different values of the kidney depth calculated by this technique as compared to lateral view technique (P = 0.4414). However, when compared to equation-derived values, there is no significant difference in the adult patients only, but significant difference in pediatric patients.

Conclusion : The kidney depth calculation using attenuation related technique is accurate, practical and can be used in most patient groups.

Downloads

Download data is not yet available.

References

Russell CD. A comparison of methods for GFR measurement using Tc-99m DTPA and the gamma camera. Three approaches to computer-assisted function studies of the kidney and evaluation of scintigraphic methods. In: Tauxe WN, Dubovsky EV, editors. Nuclear medicine in clinical urology and nephrologv. Norwalk, CT: AppletonCentury-Crofts; 1985:173-84.

Chachati A, Meyers A, Godon JP, Rigo P. Rapid method for the measurement of differential renal function: validation. J Nucl Med 1987;28:829-36.

Kohn HD, Mostheck A. Value of additional lateral scans in renal scintigraphy. Eur J Nucl Med 1979;4:21-5. https://doi.org/10.1007/BF00257565

Hartling OJ, Marving J, Munck O. Scintigraphy of kidneys located at different depths: the geometric mean method for determination of differential renal function. Clin Nucl Med 1987;12:956-7.

https://doi.org/10.1097/00003072-198712000-00013

Gruenewald SM, Fawdry RM. Kidney depth measurement and its influence on quantitation of function from gamma camera renography. Clin Nucl Med 1985;10:398-401.

https://doi.org/10.1097/00003072-198506000-00002

Vivian G, Gordon I. Comparison between individual kidney GFR estimation at 20 minutes with Tc-99m DTPA + Cr-S1 EDTA GFR in children with single kidney. Nucl Med Commun 1983; 4:108-17.

https://doi.org/10.1097/00006231-198304020-00008

Maneval DC, Magill HL, Cypess AM, Rodman JH. Measurement of skin-to-kidney distance in children: implications for quantitative renography. J Nucl Med 1990;31:287-91.

Inoue Y, Yoshikawa K, Suzuki T, Katayama N, Yokoyama I, Kohsaka T, et al. Attenuation correction in evaluating renal function in children and adults by a camera-based method. J Nucl Med 2000;41:823-9.

Raza M, Hameed A, Khan MI. Ultrasonographic assessment of renal size and its correlation with body mass index in adults without known renal disease. J Ayub Med Coll Abbottabad 2011;23:64-8.

Tnnesen KH, Munck O, Hald T, Mogensen P, Wolf H, zumWinkel K, et al, editors. Influence on the renogram of variation in skin to kidney distance and the clinical importance thereof. Presented at Radionuclides in nephrology proceedings of the 3rd International Symposium. Berlin: Acton, Mass, Publishing Sciences Group; 1975: 79-86. Cited by Schlegel JU, Hamway SA. Individual renal plasma flow determination in 2 minutes. J Urol 1976;116:282-5. https://doi.org/10.1016/S0022-5347(17)58783-2

Taylor A. Formulas to estimate renal depth in adults. J Nucl Med 1994;35:2054-5.

Itoh K, Arakawa M, Re-estimation of renal function with 99mTc-DTPA by the Gates' method. KakuIgaku 1987;24:389-96.

Downloads

Published

2023-08-24

How to Cite

1.
Sontrapornpol T, Chaiwatanarat T, Kawinthammasak C, Kamklon N, Rattanamonrot R. Kidney depth calculation by anterior and posterior renal scintigraphy using attenuation – related techniques. Chula Med J [Internet]. 2023 Aug. 24 [cited 2024 Nov. 22];61(4). Available from: https://he05.tci-thaijo.org/index.php/CMJ/article/view/463

Similar Articles

You may also start an advanced similarity search for this article.